Giỏ hàng

Use in hazardous areas

Vendor: IFM Eng
|
  • Robust metal and plastic housings with 4 joules shock test
  • Simple connection using connector or terminals
  • Clearly visible indication of the switching status
  • Direct connection to the plant control or to the switching amplifier
  • High mechanical stability

Số lượng

Sensors for hazardous dust areas of categories 3G/3D must withstand extreme requirements. Any risk from sensors must be excluded by special test methods. Selected materials and a special sensor design ensure that prevention of ignition sources is guaranteed even in long-term use. This considerably increases plant safety.
Namur sensors of the categories 1G/1D can be connected to intrinsically safe circuits. The connection to the required ifm switching amplifiers is made via connectors of the ENC ecolink series.

ProductSensing rangeOutput functionOutputDimensionsConnection
KI505A15 mm non-flush mountablecomplementaryDC PNPM30 x 1.5 / L = 125 mmterminals: 0,34...1,5 mm²; Cable sheath: Ø 5...9 mm
KI503A15 mm non-flush mountablecomplementaryDC PNPM30 x 1.5 / L = 150 mmterminals: 0,34...1,5 mm²; Cable sheath: Ø 5...9 mm
KI530A3...26 mm non-flush mountablecomplementaryDC PNPM30 x 1.5 / L = 150 mmterminals: 0,34...1,5 mm²; Cable sheath: Ø 5...9 mm
KI531A3...26 mm non-flush mountablecomplementaryDC PNPM30 x 1.5 / L = 150 mmterminals: 0,34...1,5 mm²; Cable sheath: Ø 5...9 mm
KI533A3...26 mm non-flush mountablecomplementaryDC PNPM30 x 1.5 / L = 150 mmM12 Connector
KI532A3...26 mm non-flush mountablecomplementaryDC PNPM30 x 1.5 / L = 150 mmM12 Connector
KI000A15 mm non-flush mountablenormally open / normally closed; (selectable)AC/DCM30 x 1.5 / L = 150 mmterminals: 0,34...2,5 mm²; Cable sheath: Ø 5...9 mm
KI503115 mm non-flush mountablenormally closedDC NAMURM30 x 1.5 / L = 81 mm6 m PVC-Cable
KI503015 mm non-flush mountablenormally closedDC NAMURM30 x 1.5 / L = 81 mm2 m PVC-Cable
KI001A15 mm non-flush mountablenormally open / normally closed; (selectable)AC/DCM30 x 1.5 / L = 125 mmterminals: 0,34...2,5 mm²; Cable sheath: Ø 5...9 mm
KD501A60 mm non-flush mountablenormally open / normally closed; (selectable)DC PNP105 x 80 x 42 mmterminals: 0,34...2,5 mm²; Cable sheath: Ø 5...9 mm
KD001A60 mm non-flush mountablenormally open / normally closed; (selectable)AC/DC105 x 80 x 42 mmterminals: 0,34...2,5 mm²; Cable sheath: Ø 5...9 mm
KX500115 mm non-flush mountablenormally closedDC NAMURM34 x 1.5 / L = 92 mm2 m PVC-Cable
KX500215 mm non-flush mountablenormally closedDC NAMURM34 x 1.5 / L = 92 mm6 m PVC-Cable
KG50798 mm non-flush mountablenormally closedDC NAMURM18 x 1 / L = 84 mm6 m PVC-Cable
KX500415 mm non-flush mountablenormally closedDC NAMURM34 x 1.5 / L = 92 mm20 m PVC-Ca