Capacitive sensors detect powdery bulk materials like flour or cocoa or agricultural products like grain directly or through vessel walls of silos and pneumatic conveying systems. They can be easily adapted to the respective application by adjusting the sensing range using a potentiometer. Some sensor types allow direct adjustment to the medium via the buttons on the sensor.

Capacitive sensors with AC or AC/DC output stage are suitable for use in alternating current networks. For units with combined output stage, the sensor decides which output (DC or AC) switches depending on the voltage applied.
The high sensing ranges are guaranteed over the complete temperature range.

ProductSensing rangeOutput functionOutputDimensionsConnection
KI002415 mm non-flush mountablenormally open / normally closed; (selectable)AC/DCM30 x 1.5 / L = 125 mmterminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm
KI02033…15 mm non-flush mountablenormally closedAC/DCM30 x 1.5 / L = 81 mm2 m PVC-Cable
KI020915 mm non-flush mountablenormally closedAC/DCM30 x 1.5 / L = 81 mm2 m PVC-Cable
KI02023…15 mm non-flush mountableormally openAC/DCM30 x 1.5 / L = 81 mm2 m PVC-Cable
KI001715 mm non-flush mountableormally openAC/DCM30 x 1.5 / L = 81 mm6 m PVC-Cable
KI001615 mm non-flush mountableormally openAC/DCM30 x 1.5 / L = 81 mm2 m PVC-Cable
KI00545…40 mm non-flush mountablenormally open / normally closed; (selectable)AC/DCM30 x 1.5 / L = 90 mmđầu nối 1/2″
KI02053…15 mm non-flush mountablenormally open / normally closed; (selectable)AC/DCM30 x 1.5 / L = 125 mmterminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm
KB00253…20 mm non-flush mountableormally openAC/DCØ 34 / L = 81 mm2 m PVC-Cable
KI002015 mm non-flush mountablenormally closedAC/DCM30 x 1.5 / L = 81 mm2 m PVC-Cable
KG00108 mm non-flush mountablenormally closedAC/DCM18 x 1 / L = 84 mm2 m PVC-Cable
KG00098 mm non-flush mountableormally openAC/DCM18 x 1 / L = 84 mm2 m PVC-Cable
KB00293…20 mm non-flush mountablenormally closedAC/DCØ 34 / L = 81 mm2 m PVC-Cable
KD000960 mm non-flush mountablenormally open / normally closed; (selectable)AC/DC105 x 80 x 40 mmterminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm
KI02073…15 mm non-flush mountablenormally closedAC/DCM30 x 1.5 mm
0.1 m PVC-Cable; 1/2" Connector
KG00088 mm non-flush mountablenormally open / normally closed; (selectable)AC/DCM18 x 1 / L = 110 mmterminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm